Step 1: Column and Material Data
| Parameter | Value |
|---|---|
| Column | W10x49 (A992, Fy = 50 ksi) |
| Factored load (Pu) | 400 kips |
| Plate steel | A36 (Fy = 36 ksi, Fu = 58 ksi) |
| Concrete | f'c = 4,000 psi |
| Pier size | 24 in ÃÂÃÂ 24 in |
| Column dimensions | d = 10.0 in, bf = 10.0 in |
Step 2: Required Bearing Area (AISC DG1 Section 3.1)
The concrete bearing strength per AISC 360-22 J8:
ÃÂÃÂc ÃÂàPp = ÃÂÃÂc ÃÂà0.85 ÃÂàf'c ÃÂàA1 ÃÂàâÃÂÃÂ(A2/A1)
Where:
- ÃÂÃÂc = 0.65 (bearing on concrete)
- A1 = base plate area (inÃÂò)
- A2 = concrete support area (pier area = 24 ÃÂà24 = 576 inÃÂò)
- âÃÂÃÂ(A2/A1) âÃÂä 2.0
For the initial trial, assume âÃÂÃÂ(A2/A1) = 2.0 (full confinement):
Required A1 = Pu / (ÃÂÃÂc ÃÂà0.85 ÃÂàf'c ÃÂà2.0) A1 = 400,000 / (0.65 ÃÂà0.85 ÃÂà4,000 ÃÂà2.0) A1 = 400,000 / 4,420 A1 = 90.5 inÃÂò
Try N ÃÂàB = 14 ÃÂà14 = 196 inÃÂò (A1 = 196 inÃÂò)
Check âÃÂÃÂ(A2/A1) = âÃÂÃÂ(576/196) = âÃÂÃÂ2.94 = 1.71 âÃÂä 2.0 âÃÂàOK
Check bearing capacity:
ÃÂÃÂc ÃÂàPp = 0.65 ÃÂà0.85 ÃÂà4,000 ÃÂà196 ÃÂà1.71 ÃÂÃÂc ÃÂàPp = 0.65 ÃÂà0.85 ÃÂà4,000 ÃÂà335 ÃÂÃÂc ÃÂàPp = 0.65 ÃÂà1,139,000 ÃÂÃÂc ÃÂàPp = 740 kips > 400 kips âÃÂàOK
Step 3: Plate Dimensions (DG1 Section 3.2)
Required plate dimensions:
N_min = âÃÂÃÂ(A1_req) + ÃÂÃÂ, where ÃÂà= (0.95d - 0.8bf)/2
ÃÂÃÂ = (0.95 ÃÂÃÂ 10.0 - 0.8 ÃÂÃÂ 10.0)/2 = (9.5 - 8.0)/2 = 0.75 in
N_min = âÃÂÃÂ90.5 + 0.75 = 9.51 + 0.75 = 10.26 in
B_min = A1_req / N_min = 90.5 / 10.26 = 8.82 in
Use N = 16 in, B = 14 in (A1 = 224 inÃÂò > 90.5 inÃÂò âÃÂàOK)
Bearing check with actual dimensions:
âÃÂÃÂ(A2/A1) = âÃÂÃÂ(576/224) = âÃÂÃÂ2.57 = 1.60 âÃÂä 2.0 âÃÂàOK
ÃÂÃÂcPp = 0.65 ÃÂà0.85 ÃÂà4,000 ÃÂà224 ÃÂà1.60 ÃÂÃÂcPp = 0.65 ÃÂà0.85 ÃÂà4,000 ÃÂà358.4 ÃÂÃÂcPp = 0.65 ÃÂà1,218,560 ÃÂÃÂcPp = 792 kips > 400 kips âÃÂàOK
Step 4: Plate Thickness (DG1 Section 3.3)
Cantilever dimensions (m and n):
m = (N - 0.95d)/2 = (16 - 0.95 ÃÂÃÂ 10.0)/2 = (16 - 9.5)/2 = 3.25 in
n = (B - 0.80bf)/2 = (14 - 0.80 ÃÂÃÂ 10.0)/2 = (14 - 8.0)/2 = 3.00 in
Required bearing pressure on plate:
fp = Pu / (B ÃÂÃÂ N) = 400 / (14 ÃÂÃÂ 16) = 400 / 224 = 1.79 ksi
Plate thickness by bending:
For A36 plate (Fy = 36 ksi), the required thickness:
t_min = m ÃÂàâÃÂÃÂ(2 ÃÂàfp / (0.90 ÃÂàFy))
t_min (from m direction) = 3.25 ÃÂàâÃÂÃÂ(2 ÃÂà1.79 / 32.4) = 3.25 ÃÂàâÃÂÃÂ(0.110) = 3.25 ÃÂà0.332 = 1.08 in
t_min (from n direction) = 3.00 ÃÂàâÃÂÃÂ(2 ÃÂà1.79 / 32.4) = 3.00 ÃÂà0.332 = 1.00 in
Check n' (DG1 alternative method):
n' = âÃÂÃÂ(d ÃÂàbf)/4 = âÃÂÃÂ(10.0 ÃÂà10.0)/4 = âÃÂÃÂ100/4 = 10/4 = 2.50 in
ÃÂû = min(1.0, 2 ÃÂàâÃÂÃÂ(n') / (1 + âÃÂÃÂ(1 - bearing_factor)) in tension/compression)
For simplicity with concentric load, ÃÂû = min(1.0, 2 ÃÂàn' / (m + n)):
ÃÂû = min(1.0, 2 ÃÂà2.50 / (3.25 + 3.00)) = min(1.0, 5.0/6.25) = min(1.0, 0.80)
t_min (DG1) = n' ÃÂàâÃÂÃÂ(2 ÃÂàfp / (0.90 ÃÂàFy)) ÃÂà(m ÃÂàn / (m + n)) factor...
Using the simplified DG1 approach:
l = max(m, n, ÃÂûn') = max(3.25, 3.00, 0.80 ÃÂà2.50) = max(3.25, 3.00, 2.00) = 3.25 in
t_req = l ÃÂàâÃÂÃÂ(2 ÃÂàfp / (0.90 ÃÂàFy)) = 3.25 ÃÂàâÃÂÃÂ(3.58 / 32.4) = 3.25 ÃÂà0.332 = 1.08 in
Use 1-1/4 in thick plate (next standard 1/4-in increment above 1.08 in).
Step 5: Anchor Rod Design (AISC DG1 Section 3.5)
For a pinned base (no moment), use four 3/4-in diameter anchor rods for stability and erection:
Rod material: ASTM F1554 Grade 36 (Fy = 36 ksi, Fu = 58 ksi)
Tension check: No net uplift at service loads (assume compression only). However, anchor rods must resist handling and construction loads (minimum 5 kips/rod per DG1).
Shear check: If lateral loads are small (say Vu = 20 kips at base):
Shear per rod = 20 / 4 = 5.0 kips
ÃÂÃÂvVn = ÃÂÃÂv ÃÂÃÂ 0.60 ÃÂÃÂ Fy ÃÂÃÂ A_b ÃÂÃÂ C (where C accounts for threads in shear plane)
For 3/4 in rod, A_b = 0.442 inÃÂò Assume threads are not excluded from shear plane: ÃÂÃÂvVn = 0.75 ÃÂà0.60 ÃÂà36 ÃÂà0.442 ÃÂà0.80 = 5.73 kips per rod âÃÂà5.0 < 5.73 âÃÂàOK
Step 6: Weld Design (Column-to-Base Plate)
Minimum weld per AISC 360 J2.2b: For column flange tf = 0.560 in (W10x49), minimum fillet weld = 3/16 in.
Weld at column flanges (load transfer):
Required weld strength = Pu / 2 = 200 kips per flange (assuming web carries minimal compression)
For E70XX electrodes (FEXX = 70 ksi), 3/16 in fillet weld strength:
ÃÂÃÂRn = 0.75 ÃÂÃÂ 0.60 ÃÂÃÂ 70 ÃÂÃÂ (0.707 ÃÂÃÂ 3/16) per inch = 0.75 ÃÂÃÂ 42 ÃÂÃÂ 0.1326 = 4.18 kip/in
Flange width available = bf = 10.0 in. Use two return welds of 1 in each on each flange.
Total weld length per flange = 10 + 2 ÃÂÃÂ 1 = 12 in (at two flanges = 24 in total at flanges)
Add web welds: W10x49 web depth âÃÂà8.88 in, use 3/16 in fillet both sides:
Web weld capacity = 2 ÃÂÃÂ 8.88 ÃÂÃÂ 4.18 = 74.2 kips
Total weld capacity = (2 flanges ÃÂÃÂ 12 in ÃÂÃÂ 4.18) + 74.2 = 100.3 + 74.2 = 174.5 kips
This is insufficient — need larger weld or more weld length.
Increase to 5/16 in fillet:
ÃÂÃÂRn = 0.75 ÃÂÃÂ 0.60 ÃÂÃÂ 70 ÃÂÃÂ (0.707 ÃÂÃÂ 5/16) = 0.75 ÃÂÃÂ 42 ÃÂÃÂ 0.221 = 6.96 kip/in
Total capacity = 24 ÃÂÃÂ 6.96 + 2 ÃÂÃÂ 8.88 ÃÂÃÂ 6.96 = 167 + 123.6 = 290.6 kips < 400 kips
Add stiffener plates or use CJP groove weld at flanges.
Alternative: Use complete-joint-penetration (CJP) groove weld at flanges (standard for fully-loaded columns). CJP weld capacity equals the base metal strength of the column flange. This is the typical detail for columns subject to heavy loads.
Step 7: Base Plate Stiffeners (Optional)
For a 1-1/4 in plate on a 16 ÃÂÃÂ 14 bearing area, stiffeners are not required. The cantilever distance m = 3.25 in with t = 1.25 in gives a reasonable m/t ratio of 2.6.
If plate thickness needed to be reduced (e.g., to 1 in or less), stiffeners between the column flanges and the base plate would be required. Each stiffener would be designed as a compression element (AISC E) with:
- Stiffener length = m = 3.25 in
- Minimum thickness = 3/8 in (practical minimum)
- Weld: 3/16 in fillet to column flange and base plate
Step 8: Summary
| Component | Design | Material |
|---|---|---|
| Base plate | 1-1/4 in ÃÂÃÂ 14 in ÃÂÃÂ 1 ft 4 in | A36 |
| Anchor rods | 4 ÃÂÃÂ 3/4 in dia., 12 in embedment | F1554 Gr 36 |
| Column-to-base weld | CJP at flanges, 5/16 in fillet at web | E70XX |
| Concrete pier | 24 in ÃÂÃÂ 24 in, f'c = 4,000 psi | — |
| Design bearing pressure | 1.79 ksi | — |
| Bearing utilization | 400/792 = 0.50 (50%) | — |
| Plate bending utilization | 1.08/1.25 = 0.86 (86%) | — |
Try the Calculator
Use the Base Plate & Anchors Calculator to design base plates for your own column sections, loads, and concrete strengths. Supports AISC DG1, AS 4100, EN 1993-1-8, and CSA S16.
Frequently Asked Questions
What is the concrete confinement factor âÃÂÃÂ(A2/A1) and when does it apply? The confinement factor accounts for the increased bearing capacity of concrete when the loaded area is smaller than the total support area. The confining concrete surrounds the bearing area and resists lateral expansion, triaxially confining the concrete under the plate. It applies only when the base plate is not at the edge of the concrete pier (minimum 4 in edge distance on all sides for full development). For edge conditions, use âÃÂÃÂ(A2/A1) = 1.0.
When should I use stiffeners on base plates? Stiffeners are typically needed when:
- Plate thickness exceeds 2 in (economy)
- Cantilever dimension m or n exceeds 6-8 in
- Large moment is present (moment-resisting base plate)
- Column size is small relative to the base plate area The DG1 alternative method (n' and ÃÂû) helps determine whether stiffeners are actually needed or if a thicker plate is more economical.
How do I design a base plate for moment (not just axial load)? Moment-resisting base plates follow DG1 Section 3.4. The approach distributes the moment to the flanges as a tension-compression couple. The tension side requires anchor rods designed per AISC 360 J3 (tension + shear interaction), while the compression side follows the same bearing design as above. The plate thickness is governed by the maximum moment from either the compression cantilever (m) or the tension anchor rod cantilever distance.
What is the minimum edge distance for anchor rods? Per AISC 360 Table J3.4M, the minimum edge distance for a 3/4 in anchor rod in a rolled edge is 1-1/8 in. For concrete edge distances, ACI 318-19 Chapter 17 requires minimum edge distance of 1.5 ÃÂÃÂ anchor diameter (1.125 in for 3/4 in) but recommends 4-6 in for proper development of the concrete breakout cone.
See Also
Disclaimer: This content is for educational purposes only. Results must be verified by a licensed professional engineer. Steel Calculator provides preliminary design tools — NOT a substitute for professional engineering judgment.